%0期刊文章%@ 1438-8871 %I JMIR出版物%V 24%卡塔尔世界杯8强波胆分析 N 1% P e27487% T在时域和频域上与心电图比较的Oura环夜间心率和心率变异性的准确性评估:综合分析%A Cao, %A Azimi,Iman %A Sarhaddi,Fatemeh %A Niela-Vilen,Hannakaisa %A Axelin,Anna %A Liljeberg,Pasi %A Rahmani,Amir M %+加州大学电气工程和计算机科学系,1407 Palo Verde Rd, Irvine, CA, 92617, United States, 1 6266883017, caor6@uci.edu %K心电图%K ECG %K可穿戴设备%K心率变化率%K Oura智能戒指%D 2022 %7 18.1.2022 %9原创论文%J J Med Internet Res %G英文%X背景:光容积描记术是一种远程连续跟踪生命体征的无创低成本方法。Oura Ring是一款紧凑的基于光电体积描记术的智能戒指,最近引起了人们对远程健康监测和保健应用的关注。该戒指普遍用于获取夜间心率(HR)和心率变异性(HRV)参数。然而,这些参数很容易受到运动伪影和环境噪声的影响。因此,在日常设置中需要对参数进行有效性评估。目的:本研究旨在评价Oura Ring收集的HR及时域频域HRV参数与医用级胸电监护仪的准确性。方法:我们使用Oura Ring和Shimmer3心电图仪进行夜间家庭监测。收集并评估35例健康个体的夜间HR和HRV参数。 We evaluated the parameters within 2 tests, that is, values collected from 5-minute recordings (ie, short-term HRV analysis) and the average values per night sleep. A linear regression method, the Pearson correlation coefficient, and the Bland–Altman plot were used to compare the measurements of the 2 devices. Results: Our findings showed low mean biases of the HR and HRV parameters collected by the Oura Ring in both the 5-minute and average-per-night tests. In the 5-minute test, the error variances of the parameters were different. The parameters provided by the Oura Ring dashboard (ie, HR and root mean square of successive differences [RMSSD]) showed relatively low error variance compared with the HRV parameters extracted from the normal interbeat interval signals. The Pearson correlation coefficient tests (P<.001) indicated that HR, RMSSD, average of normal heart beat intervals (AVNN), and percentage of successive normal beat-to-beat intervals that differ by more than 50 ms (pNN50) had high positive correlations with the baseline values; SD of normal beat-to-beat intervals (SDNN) and high frequency (HF) had moderate positive correlations, and low frequency (LF) and LF:HF ratio had low positive correlations. The HR, RMSSD, AVNN, and pNN50 had narrow 95% CIs; however, SDNN, LF, HF, and LF:HF ratio had relatively wider 95% CIs. In contrast, the average-per-night test showed that the HR, RMSSD, SDNN, AVNN, pNN50, LF, and HF had high positive relationships (P<.001), and the LF:HF ratio had a moderate positive relationship (P<.001). The average-per-night test also indicated considerably lower error variances than the 5-minute test for the parameters. Conclusions: The Oura Ring could accurately measure nocturnal HR and RMSSD in both the 5-minute and average-per-night tests. It provided acceptable nocturnal AVNN, pNN50, HF, and SDNN accuracy in the average-per-night test but not in the 5-minute test. In contrast, the LF and LF:HF ratio of the ring had high error rates in both tests. %M 35040799 %R 10.2196/27487 %U //www.mybigtv.com/2022/1/e27487 %U https://doi.org/10.2196/27487 %U http://www.ncbi.nlm.nih.gov/pubmed/35040799
Baidu
map