TY - JOUR AU - Cao, Rui AU - Azimi, Iman AU - Sarhaddi, Fatemeh AU - Niela-Vilen, Hannakaisa AU - Axelin, Anna AU - Liljeberg, Pasi AU - Rahmani, Amir M PY - 2022 DA - 2022/1/18 TI - Oura环夜间心率和心率变异性在时域和频域上与心电图比较的准确性评估:综合分析JO - J Med Internet Res SP - e27487 VL - 24 IS - 1kw -心电图KW - ECG KW -可穿戴设备KW -心率变异性KW - Oura智能戒指AB -背景:光容积描记术是一种远程连续跟踪生命体征的无创和低成本方法。Oura Ring是一款紧凑的基于光电体积描记术的智能戒指,最近引起了人们对远程健康监测和保健应用的关注。该戒指普遍用于获取夜间心率(HR)和心率变异性(HRV)参数。然而,这些参数很容易受到运动伪影和环境噪声的影响。因此,在日常设置中需要对参数进行有效性评估。目的:本研究旨在评价Oura Ring收集的HR及时域频域HRV参数与医用级胸电监护仪的准确性。方法:我们使用Oura Ring和Shimmer3心电图仪进行夜间家庭监测。收集并评估35例健康个体的夜间HR和HRV参数。我们评估了两次测试中的参数,即从5分钟记录中收集的值(即短期HRV分析)和每晚睡眠的平均值。 A linear regression method, the Pearson correlation coefficient, and the Bland–Altman plot were used to compare the measurements of the 2 devices. Results: Our findings showed low mean biases of the HR and HRV parameters collected by the Oura Ring in both the 5-minute and average-per-night tests. In the 5-minute test, the error variances of the parameters were different. The parameters provided by the Oura Ring dashboard (ie, HR and root mean square of successive differences [RMSSD]) showed relatively low error variance compared with the HRV parameters extracted from the normal interbeat interval signals. The Pearson correlation coefficient tests (P<.001) indicated that HR, RMSSD, average of normal heart beat intervals (AVNN), and percentage of successive normal beat-to-beat intervals that differ by more than 50 ms (pNN50) had high positive correlations with the baseline values; SD of normal beat-to-beat intervals (SDNN) and high frequency (HF) had moderate positive correlations, and low frequency (LF) and LF:HF ratio had low positive correlations. The HR, RMSSD, AVNN, and pNN50 had narrow 95% CIs; however, SDNN, LF, HF, and LF:HF ratio had relatively wider 95% CIs. In contrast, the average-per-night test showed that the HR, RMSSD, SDNN, AVNN, pNN50, LF, and HF had high positive relationships (P<.001), and the LF:HF ratio had a moderate positive relationship (P<.001). The average-per-night test also indicated considerably lower error variances than the 5-minute test for the parameters. Conclusions: The Oura Ring could accurately measure nocturnal HR and RMSSD in both the 5-minute and average-per-night tests. It provided acceptable nocturnal AVNN, pNN50, HF, and SDNN accuracy in the average-per-night test but not in the 5-minute test. In contrast, the LF and LF:HF ratio of the ring had high error rates in both tests. SN - 1438-8871 UR - //www.mybigtv.com/2022/1/e27487 UR - https://doi.org/10.2196/27487 UR - http://www.ncbi.nlm.nih.gov/pubmed/35040799 DO - 10.2196/27487 ID - info:doi/10.2196/27487 ER -
Baidu
map